Electrochemistry Meters
Filtered Search Results
Mettler Toledo™ FiveEasy™ F30 Conductivity Meters
Compact, benchtop meter provides high quality conductivity measurements with simple click of a button
| Resolution (Conductivity) | Automatic range |
|---|---|
| Memory | Current calibration |
| Range (Conductivity) | 0.01 μS/cm to 200 mS/cm |
| Range (TDS) | 0 mg/L to 300 mg/L |
| Measurement Modes | Conductivity |
| Calibration | One point calibration with three predefined standards |
| Range (Salinity) | 0 to 42 psu |
| Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
| Temperature Compensation | Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C |
| Display Type | LCD |
| Voltage | 100/240 V |
| Accuracy (Conductivity) | ±0.5% of the measured value |
| Model | F30 |
| Frequency | 50/60Hz |
| Data Points | 200 |
| Temperature Range (English) | 32°F to 212°F |
| Weight (English) | 1.4 lb. |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | -5°C to +105°C |
| Inputs | Mini-DIN |
| Accuracy (Temperature) | 0.5°C |
| Weight (Metric) | 0.63 kg |
Thermo Scientific™ Orion Lab Star DO Dissolved Oxygen Bench Meters
Orion Lab Star DO113 dissolved oxygen bench meters measure DO as % saturation or concentration with temperature, feature large backlit display for easy viewability, and offer small footprint to save bench space. This DO meter is ideal for simplified, budget-friendly lab testing and data recording.
| Temperature (Metric) Range | -5.0°C to +105.0°C |
|---|---|
| Resolution (Polarographic DO) | 0.1, 1 % saturation; 0.01, 0.1 mg/L or ppm |
| Pressure Range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Memory | Non-volatile |
| Measurement Modes | Dissolved Oxygen (% Saturation with Temperature),Dissolved Oxygen (mg/L with Temperature),Dissolved Oxygen (ppm with Temperature) |
| Data Management Details | Continuous, Auto-Read and Timed read modes |
| Display Type | 5 in. backlit LCD |
| Data Points | 500 Sets with Date and Time Stamp |
| Calibration Modes | 100 % saturation, 0 % saturation, custom concentration value |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Accuracy (Temperature) | ±0.3°C, ±0.5°F |
| Weight (Metric) | 700 grams |
| Warranty | 3 year meter warranty |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Sensor Types | Polarographic |
| Percent Saturation Range Polarographic DO | 0.0 to 300.0 % saturation |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Alarm Output | Calibration reminder alarm |
| Dimensions (L x W x H) | 187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in. |
| IP Rating | IP54 |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Outputs | Computer or printer (STARA-106) |
| Backlight Option | Yes |
| Weight (English) | 1.54 lb. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Range (Polarographic DO) | 0.0 to 300.0 % saturation; 0.00 to 30.0 mg/L or ppm |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter
Get premium performance and flexibility with our multiparameter benchtop meter with pH/ISE, conductivity and RDO/DO modules to measure up to four channels at once.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
| Pressure Range | 400 to 850mmHg |
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Resolution (pH) | 0.1/0.01/0.001 |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature,TDS,Conductivity,Salinity |
| Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
| Power Supply | Universal AC adapter (included) |
| Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 6 |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Range (RDO) | 0.00 to 50.00mg/L |
| Dimensions (L x W x H) | 28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Percent Saturation Range (RDO) | 0.0 to 500.0% saturation |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation ≤ 200% saturation, ±10% saturation > 200% saturation |
| Range (Polarographic DO) | 0.00 to 90.00mg/L |
| Range (mV) | ±2000.0 mV |
| Accuracy (Barometer) | ±6 mmHg |
| Range (ORP) | ±2000.0 mV |
| Pressure Resolution | 0.1mmHg |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5°, 10°, 15°, 20°, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Resolution (RDO) | 0.01, 0.1mg/L |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Calibration Points (Conductivity) | Up to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
| Accuracy (Polarographic DO) | ±0.2 mg/L or ±2% of reading, whichever is greater |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| IP Rating | IP54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0% saturation |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L |
Fisherbrand™ Traceable™ pH/ORP/Temperature Meter
Measure critical water quality parameters — without the need to carry multiple units.
Fisherbrand™ accumet™ AR450 pH/ion/Conductivity Meter Kit
Designed to deliver precise and reliable electrochemistry testing, the accumet AR450 offers enhanced performance in a streamlined design. Ideal for laboratories requiring dependable measurement capabilities.
Fisherbrand™ Traceable™ Salinity Meter Pen
Easy-to-use and splash-proof salinity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Fisherbrand™ Traceable™ Conductivity Meter Pen
Easy-to-use, waterproof conductivity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Fisherbrand™ accumet™ AR450 pH/ion/Conductivity Meter with Stand
Designed to deliver precise and reliable electrochemistry testing, the accumet AR450 offers enhanced performance in a streamlined design. Ideal for laboratories requiring dependable measurement capabilities.
Fisherbrand™ Traceable™ Expanded Range Conductivity Meter
Ideal for checking the purity of water from stills, deionizers, and reverse osmosis, testing laboratory glassware rinsing, measuring total dissolved solids, and making solutions.
Thermo Scientific™ Orion™ Pro Star PC215 pH/ion and Conductivity Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PC215 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Range (Resistivity) | 1.0 Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Range (mV) | -2000 to 2000 mV |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Accuracy (Conductivity) | ±0.5% reading |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Calibration Points (Conductivity) | 1 to 5 points |
| Resolution (Resistivity) | 0.1 Ω minimum, auto-ranging |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion Star™ A222 Conductivity Portable Meter
Reliably measure conductivity, TDS, salinity, resistivity and temperature with this conductivity portable meter for advanced field analysis.
| Salinity Measurement Modes | Practical salinity (psu) |
|---|---|
| Range (Resistivity) | 2 ohm to 100.0 megohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | Conductivity,TDS,Salinity,Resistivity with Temperature |
| Battery Life | 800 hr. |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Graphic LCD with Backlight |
| Data Points | 1000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Stability | Smart Stability and Smart Averaging |
| Warranty | 3 Year Meter |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read Measure Mode, Manual with Continuous Measure Mode |
| Battery Type | 4 x AA (included) |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Dimensions (L x W x H) | 24 x 10 x 6.5 cm (9.5 x 3.9 x 2.6 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Backlight Option | Yes (Selectable) |
| Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
| Methods | 10 per channel with password protection |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 15, 20, 25°C |
| Channels | 1 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 0.5 kg |
| Calibration Points (Conductivity) | 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | Conductivity and temperature |
| Alarm Output | Calibration due alarm (fixed 12 hour) |
| IP Rating | IP67 |
| Model | Orion Star A222 Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5°C to +105°C |
Thermo Scientific™ Orion™ Pro Star PI217 Dual Channel pH/Ion Bench Meter
Designed to provide accurate and reliable pH, ORP, ion concentration and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PI217 dual channel bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Temperature (Metric) Range | -30.0°C to +130.0°C |
|---|---|
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH,ORP with mV and Temperature,Ion Concentration (ISE) with Temperature |
| Range (pH) | -2 to 20 |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Data Points | 10,000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference |
| Accuracy (Temperature) | ±0.3°C, ±0.5°F |
| Weight (Metric) | 1.00 kg |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Calibration Points (ISE) | Up to 5 |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Calibration | pH, ORP, Ion Concentration, Temperature |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Model | PI217 |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Weight (English) | 2.20 lbs. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Range (mV) | -2000 to 2000 mV |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
YSI™ IDS ProOBOD™ Self-stirring Optical BOD Probe
For use with MultiLab 4010-1, 4010-2, or 4010-3 instruments.
Fisherbrand™ accumet™ AR430 Conductivity Meter with Stand
Designed to deliver precise and reliable electrochemistry testing, the accumet AR430 offers enhanced performance in a streamlined design. Ideal for laboratories requiring dependable measurement capabilities.
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter
Accurate measurements any time, anywhere
| Accuracy (mV) | 0 to ±2000mV |
|---|---|
| Warranty | 3 Years |
| Resolution (pH) | Adjustable |
| Measurement Modes | pH,Ion,mV,Temperature |
| Range (pH) | 2 to 20 |
| Range | -2 to +20pH |
| For Use With (Application) | pH, Ion concentration, mV, Temperature |
| Includes | Meter, 9V battery, manual |
| Calibration Points | 10 |
| Accuracy | Multiple |
| Display Type | LCD |
| Product Type | Meter Only |
| IP Rating | IP67 |
| Temperature Range (English) | 23°F to 212°F |
| Data Points | 200 |
| Temperature Range (Metric) | -5°C to +100°C |
| Range (mV) | 0 to ±2000 mV |
| Resolution | Multiple |